Printable Page
|
 |
SLAC
Series
AC Power/SignalNEMA-4X
The SLAC Series suppressor was specifically
designed to protect electronic instruments used by the water and
wastewater industries. It combines hybrid AC power protection and
signal line protection in a NEMA-4X polycarbonate case. The AC power
suppressor can supply up to 1875 Watts and has a 15-Amp replaceable
fuse to prevent overloading of the protective elements. A "Power
ON" LED provides visual indication that power is applied to
instruments. Signal line protection is accomplished by the PC642
Series available in a variety of voltage clamps. Signal current
can be monitored by reading the voltage across the 10-Ohm, 1% resistors
(TP1 & TP @ or TP3 & TP4). All leads going to the SLAC
board are terminated by quick disconnect or barrier block connectors
to facilitate easy removal for service or replacement.
| FEATURES |
| • Lightning
& Surge Suppression for AC Power and Low-Voltage Signal
Lines |
| • Series
Hybrid AC Suppressor/Filter |
| • Plug-In
Protection Module |
| • 15-Amp
Replaceable Fuse |
| • Test
Jacks for Signal Line Monitoring |
| • "Power
ON" Indicator |
• Optional
Stainless Steel or
Fiberglass Enclosure |
|
|
| STANDARD
ENCLOSURE |
| • NEMA-4X |
| • Glass-filled
polycarbonate base |
| • Cover
molded in clear polycarbonate |
| • Knockouts
for 1/2" and 3/4" hubs |
| • Bosses
for 6 BZ x 3/8" self-tapping screws |
| • Maximum
protectionTotal insulation |
| • Corrosion
resistant |
| • Resists
temperature of 248°F |
| • Flammability
rating UL94-5V |
• Nominal
outside dimensions (inches)
H= 6.89, W=6.89, D=2.95 |
|
|
| SPECIFICATIONS
AC POWER |
| Technology |
Three-Stage Series Hybrid |
| Input Voltage |
120 VAC 50/60 Hz |
| Output Current |
15 Amps max |
| Response Time |
<5 nanoseconds |
| Maximum Surge Current (8x20µs) |
10kA |
| Occurrences at 500 Amps |
>50 |
| Parameter |
Normal
Mode
(L-N) |
Common
Mode
(LG)(NG) |
| IEEE
587 CAT A Ring* |
172V |
280V |
| IEEE 587 CAT B Ring* |
205V |
280V |
| IEEE 587 CAT B Impulse* |
330V |
360V |
| *Measured
from zero volts, 90° Phase angle |

|
| OPTIONAL
ENCLOSURE |
| • NEMA-4X |
| • Stainless
Steel or Fiberglass |
| • Continuous
Hinge |
• Nominal
Outside Dimensions (inches)
H=10, W=8, D=4 |
|
 |
| SPECIFICATIONS
SIGNAL LINE |
| Technology |
Series Hybrid |
| Peak Surge
Current |
10kA |
| Response Time |
<1 nanosecond |
| Voltage Clamp (customer
selected) |
8200 Volts |
| Series Resistance |
5 Ohms (typical) |
|
|
 |

|
 |