SPA-60B
Series
120VAC Interconnect Signal
The SPA-60B is an economical method
of protecting circuitry associated with 120VAC interconnect signal
lines commonly used in traffic control systems.
In the presence of normal interconnect line voltage and frequency
(60Hz), the SPA-60B possesses the
ideal characteristics of high impedance across the protector and
no impedance in series with the line. In the presence of transients,
the protector appears as very low impedance, thereby shunting the
surge to ground.
The product is offered in four variations. The SPA-60BL
protects one circuit and is furnished with two leads. The SPA-60BL-2
is identical except it protects two circuits and is furnished with
three leads.
The SPA-60BS protects one circuit
and consists of one lead and a stud (also used for mounting). The
SPA-60BS-2 is identical except it
protects two circuits and consists of two leads and a stud. Refer
to ORDERING INFORMATION below.
| SPECIFICATIONS |
| Peak Surge Trip Point: |
| 600
Volts/Microsecond Impulse |
<
890 volts nominal |
| 3000
Volts/Microsecond Impulse |
<
950 volts nominal |
| Surge Response
Time |
<
200 nanoseconds at 10kV/µs |
| Surge Handling Ability: |
| Peak
Current (single pulse, 8x20µs) |
20,000
amps per circuit |
| Occurrences
@ 10kA |
25
times minimum |
| Discharge Voltage |
<
200 volts @ 1000 amps |
| Insulation Resistance |
>100
megohms |
| Operating Line
Voltage |
120VAC,
RMS single phase |
| Absolute Maximum
Operating Line Current |
1 ampere |
| Temperature
Range |
40°C
to +85°C |
| Size: |
|
| BL
Types |
1.50
in. x .5 in. x .8in. |
| BS
Types |
1.05"
square |
| Weight |
2
oz. |
| Mounting Studs |
No.
10:32 x 3/8 in. S.S. |
| Leads |
12
in., #14 AWG |
NOTE: This
product is intended for use on 120VAC interconnect lines.
Do not use on AC service or power lines.
|
|
| FEATURES |
| • Reduces
Costly Damage to Equipment |
| • Clamps
Over Voltage Surges caused by Lightning or Switching Transients |
| • Responds
in Nanoseconds |
| • Automatic
Recovery |
| • Very
Economical |
| • Ideal
for 120VAC Interconnect |
| • Handles
Repeated Surges |
|
|
| INSTALLATION
|
Stud Mounting
Unit:
Connect black lead to interconnect signal line near entry
point into cabinet. Shorten lead as much as possible.
Bolt unit to clean metal surface bonded to power/earth
ground (cabinet in most cases).
Lead Supported Unit:
Shorten leads. Connect between the interconnect signal
line and power/earth ground.
|
|
| ORDERING
INFORMATION |
|
|
|
|

|
 |