# SignalSRA-6LC Series
Vehicle Loop Detector

The SRA6LC Series are three terminal devices, two of which are connected across the signal inputs of the detector for differential mode protection, and the third is grounded to protect against common mode damage.

This unit addresses over voltage transients on both Common and Differential modes with state-of-the-art silicon breakover devices. The SRA6LC Series is intended for all popular makes of loop detectors presently on the market.


SPECIFICATIONS
Peak Surge Current:
   8x20µs (Differential Mode) 400 Amps
   8x20µs (Common Mode) 1000 Amps
Life Expectancy (Occurrences):
   8x20µs (200A) 500 (Typ)
   10x700µs (100A) 100 (Typ)t
Response Time < 5 ns
Input Capacitance 35pf
Clamping Voltage (After Breakover) < 25V
Breakover Voltage 150V (typ.)
Operating Temperature –40°C to +85°C
Weight 3 oz.
Dimensions:
   SRA6LC 1.2" Square cube
   SRA6LC W/LEADS 1.2" Square cube
Mounting:
   SRA6LCA-716 7/16" Terminal Strip Spacing
   SRA6LCA-916 9/16" Terminal Strip Spacing
   SRA6LCB 9/16" Terminal Strip Spacing
   SRA6LCBLL 9/16" Terminal Strip Spacing


FEATURES
• Lightning Protection for Vehicle Loop Detectors
· Solid State Protection
· Differential Protection
· Common-Mode Protection
· Automatic Recovery
· Fast Response Time
· Compatible with Digital Detectors
· Epoxy Encapsulated
· Years of Dependable Service
· Easily Installs

 

 
ORDERING INFO
SRA6LC Cube, 2 leads + stud
SRA6LC W/LEADS Cube, 3 leads/no stud
SRA6LCA-716 3 Spaded Term. Block 7/16 Spacing
SRA6LCA-916 3 Spaded Term. Block 9/16 Spacing
SRA6LCB 2 Spaded Term. Block w/ 3.5" Gnd Wire
SRA6LCBLL 2 Spaded Term. Block w/ 11" Gnd Wire
INSTALLATION
General: Units are installed as close as practical to the point where the detector loop wires enter the controller cabinet. Connect one of the leads to each loop. The common (either the bolt, green wire or center clip) connection must be connected to earth ground. Best performance is obtained by: (1) shortening the leads as much as possible, and (2) providing the lowest impedance to ground.
The SRA6LCA slips under the equipment-side screws of the terminal strip. The protector ground is the center spade of the 3 spade terminations. The terminal strip must jumper this corresponding position to ground. Protectors can be mounted consecutively along the terminal strip.

One SRA6LCA is used on each loop detector circuit to be protected.

SRA-6LC Drawing

The SRA6LCB slips under the equipment-side screws of the terminal strip. The protector ground wire must be bonded in a short, direct manner to the cabinet power ground. Protectors can be mounted consecutively along the terminal strip.

One SRA6LCB is used on each loop detector circuit to be protected.

The SRA6LC has mounting brackets available for installing multiple units in the controller cabinet. The brackets are capable of mounting four or eight devices in-line.

One SRA6LC is used on each loop detector circuit to be protected.

CAUTION: Installation and service should be performed by qualified technicians or service personnel.